Gamma-W1-T7: gate PSOLA's two untested wires, fix the cadence test's contradictory rationale, add a vacuity guard
This commit is contained in:
@@ -50,7 +50,11 @@ namespace reasampler::instrument::engine {
|
||||
// The fix is not a wider window: it is a nominal jump that is a whole number of the source's
|
||||
// own periods, so an aligned landing point exists by construction (pitch_shift.h's
|
||||
// periodAlignedJump, fed by period_detect at load). The same measurements then read 0.00% and
|
||||
// 0.00%, and 29 Hz renders at +0.0 cents. What survives: a period longer than the reachable
|
||||
// 0.00%, and 29 Hz renders at +0.0 cents — all from `preserve_low_frequency_tests` (Release,
|
||||
// hand-run; it is not in the gated ctest set), the same harness/config as the 3.6%/15.5%/-133
|
||||
// cents readings above. The gated suite's own number for this is the floor-relative excess in
|
||||
// pitch_shift_tests' testThirtyHertzSplicesAlignOnceTheSourcePeriodIsKnown, a different
|
||||
// quantity from the raw percentages here. What survives: a period longer than the reachable
|
||||
// jump (~1.25 windows, so below ~16 Hz at 50 ms) still cannot align, and a source with no
|
||||
// single period falls back to this fixed-window geometry by design.
|
||||
inline constexpr double kStretchRateMin = 0.5;
|
||||
|
||||
Reference in New Issue